sanketss84.github.io

Ender3 S1 Pro Retraction Test Findings

Author: Sanket Sonavane
Publish Date: 2023-03-11
Last Updated: 2023-03-12

Hello! Dear Visitor the site is now migrated to sanketsjournal.com
It has a better design, dark mode, article search and category pages.
All my findings and latest adventures will be published on the new address.
Hope you enjoy the new experience.


NOTE:
This is a live article i.e. as and when new information is observed or found it will be

  1. appended with time stamps to the end
  2. corrected in place, if earlier documentation was incorrect

what I am using

quick summary

after a lot of tests and trying to find the best value so far I have found that for Ender 3 S1 PRO with esun PLA+ filament produced best results

I have not been able to better the fine threads much despite all tests 0.7 and 0.8mm are sweet spots.

common settings for all retraction tests

approaches to try

these are summary of suggestions which I have received from various communities on discord and reddit

test results

2023-03-11

2023-03-11 conclusions

safe retraction speeds

according to wevolver.com article retraction speeds of 30~50mm/s are safe for Ender3 and I have tried to remain in these levels while performing my tests

Quoting a few points from the same article

Note that some slicers (e.g. Cura) will allow you to set different speeds for retraction (pulling the filament back) and priming (returning the filament to its original position). However, if these fields are left blank, then the overall retraction speed will apply in both situations.

Recommended Ender 3 retraction speed: 50 mm/s, decreasing in increments of 5 mm/s if filament grinding occurs

retraction calibration tool

2023-03-12

Retraction Calibration Tool this is an interesting test to help narrow down the retraction settings.

This is how I set the two tests up

attempt 1

2023-03-12

top
top

top-2
top-2

front
front

right
right

back
back

left
left

front-right
front-right

front-left
front-left

back-right
back-right

back-left
back-left

observations

attempt 2

2023-03-12

top
top

front
front

right
right

back
back

left
left

front-threads
○front-threads

right-threads
○right-threads

back-threads
○back-threads

left-threads
○left-threads

front-right
front-right

back-left
back-left

observations

normal retraction tower test

to test all the results of the above test here is the output of

retraction distance 0.8mm retraction speed 40mm/s fan speed 100% and this looks good.

[IMAGE ADD]

retraction distance 0.7mm retraction speed 40mm/s fan speed 100% and this looks good as well.

[IMAGE ADD]

fan speed tests

2023-03-12

attempt 1

retraction distance at 0.7mm and speeds at 40mm/s for this test

references

reddit

retraction calibration tool

articles

teaching tech articles and videos